Bathroom Vent Pipe In Attic
Otherwise the exhaust duct gets too cold when it runs through the attic.
Bathroom vent pipe in attic. When venting a bathroom exhaust fan make sure to vent the air to the outside rather than into your attic where it can cause mold and mildew to form. A cold duct allows condensation of moist indoor air leading to drips from the exhaust fan. Does bathroom vent piping need to be insulated. Condensation can be a problem in an uninsulated attic so the homeowners trades resource center recommends installing rigid pipe with a minimum slope of 1 8 inch per foot toward the vent outlet to keep water away from the fan.
Duct already wrapped in insulation at home centers. You can find 4 in. Exhausting of the bath vent fan must indeed be to the building exterior. One in line centrifugal fan can be mounted in the attic to exhaust the moisture from two bathrooms.
If this pipe is not insulated the heat carried in the air transferred to the pipe will cause condensation and potentially cause water damage at your ceiling or in your attic. The reason exhaust pipes are insulated in unconditioned spaces your attic is because they carry warm and moist air from your home to outside. Dumping bathroom exhaust into an attic or under roof space invites costly mold contamination frost under the roof in freezing climates moisture damage to roof sheathing possibly even plywood delamination or rot roof failures and shorter roof shingle life. Your attic is not a temperature controlled environment is never the same temperature as your living space and generally closer to the temperature outside.
Both bathrooms are vented by a single in line fan that has one exhaust vent running through the roof. Each fan vents separately out the roof. Exhaust air from toilet rooms and bathrooms shall not discharge into attic crawl space or other areas inside building. You should never exhaust the bathroom fan directly into the attic.
Is there any particular type of piping to be used through the attic metal ductwork pvc etc. In some localities the building department may require the use of r 3 to r 8 fiberglass pipe insulation to control condensation and even when it isn t required it s a good idea to use it especially if the vent opening is likely to ice up during the winter. Each bathroom has its own exhaust fan. Bathroom exhaust fans perform an important function by removing excess moisture from your home.
Example model ventilation codes. See bathroom vent duct termination for details about how to terminate the bath exhaust vent duct. No you cannot vent your bathroom exhaust fan into the attic.